In which way proportional valves are controlled solely by current?Having trouble understanding amps, watts,...
Split a number into equal parts given the number of parts
Canadian citizen, on US no-fly list. What can I do in order to be allowed on flights which go through US airspace?
Why can't we use freedom of speech and expression to incite people to rebel against government?
Has Wakanda ever accepted refugees?
Where is this quote about overcoming the impossible said in "Interstellar"?
Deal the cards to the players
I can't die. Who am I?
Why is it "take a leak?"
Should we avoid writing fiction about historical events without extensive research?
Has a sovereign Communist government ever run, and conceded loss, on a fair election?
Learning to quickly identify valid fingering for piano?
How do I get the first element while continue streaming?
Create chunks from an array
What is better: yes / no radio, or simple checkbox?
Is there a math equivalent to the conditional ternary operator?
How do you make a gun that throws swords?
Correct physics behind the colors on CD (compact disc)?
Practical reasons to have both a large police force and bounty hunting network?
Are there other characters in the Star Wars universe who had damaged bodies and needed to wear an outfit like Darth Vader?
Can a space-faring robot still function over a billion years?
ToC header appears in next chapter
GPL code private and stolen
Sometimes a banana is just a banana
How do we objectively assess if a dialogue sounds unnatural or cringy?
In which way proportional valves are controlled solely by current?
Having trouble understanding amps, watts, voltage, and how they all workVoltage current relationshipConfusion about current and voltage12V solenoid drawing more current than it needsIf V=IR Why are voltage and current interchangeable through a constant resistanceHigh side regulation of current for proportional valveWhy are voltage and current directly proportional?12 Volt vs a 24 Volt MotorQuestions about a remote relay control application with a MOSFETCould someone explain dither signal?
$begingroup$
Proportional valves are drived by current because we need a steady force and since resistance changes with temperature if they were driven by voltage this force wouldn't be steady.
Ok, this is what I read. What I don't understand is how can a device be driven only by current and not by voltage if voltage is the cause of current?
voltage current control-system solenoid-valve
$endgroup$
add a comment |
$begingroup$
Proportional valves are drived by current because we need a steady force and since resistance changes with temperature if they were driven by voltage this force wouldn't be steady.
Ok, this is what I read. What I don't understand is how can a device be driven only by current and not by voltage if voltage is the cause of current?
voltage current control-system solenoid-valve
$endgroup$
1
$begingroup$
The answer is on the wiki third paragraph. There are several implementations on it as well.
$endgroup$
– Huisman
yesterday
add a comment |
$begingroup$
Proportional valves are drived by current because we need a steady force and since resistance changes with temperature if they were driven by voltage this force wouldn't be steady.
Ok, this is what I read. What I don't understand is how can a device be driven only by current and not by voltage if voltage is the cause of current?
voltage current control-system solenoid-valve
$endgroup$
Proportional valves are drived by current because we need a steady force and since resistance changes with temperature if they were driven by voltage this force wouldn't be steady.
Ok, this is what I read. What I don't understand is how can a device be driven only by current and not by voltage if voltage is the cause of current?
voltage current control-system solenoid-valve
voltage current control-system solenoid-valve
asked yesterday
veronikaveronika
192210
192210
1
$begingroup$
The answer is on the wiki third paragraph. There are several implementations on it as well.
$endgroup$
– Huisman
yesterday
add a comment |
1
$begingroup$
The answer is on the wiki third paragraph. There are several implementations on it as well.
$endgroup$
– Huisman
yesterday
1
1
$begingroup$
The answer is on the wiki third paragraph. There are several implementations on it as well.
$endgroup$
– Huisman
yesterday
$begingroup$
The answer is on the wiki third paragraph. There are several implementations on it as well.
$endgroup$
– Huisman
yesterday
add a comment |
3 Answers
3
active
oldest
votes
$begingroup$
A voltage regulator allows the load to take the current it wants, while forcing the terminal voltage to remain constant.
A current regulator allows the load to determine the terminal voltage it wants, while forcing the current to remain constant.
Either can be implemented with a mainly voltage-output stage (like an emitter or source follower) or mainly current-output stage (like a collector or drain). The only difference is which of the output voltage or output current is sensed and fed-back to control the output stage.
To address your main point, voltage is not the 'cause of current'. At least, not in the sense that stops 'current is the cause of voltage' also being true at the same time. You set up the conditions, and current flows. While you can calculate numerically what's happening, arguing around the word 'cause' is going to confuse you.
$endgroup$
add a comment |
$begingroup$
"Controlled by current" does not mean that no voltage is required (although that might be true in some specialized situations), it means that current is what determines the action of the valve. So you should adjust the voltage in order to maintain a certain current if you want the valve "position" to be relatively stable. That adjustment is done automatically by a "constant current" circuit.
In the case of an electromagnet as in such a valve (or a relay for that matter) the mechanical force is proportional to the current through the coil**. The voltage, for a given current, will change depending on the temperature of the coil, so a constant current circuit should not only start off with a voltage dependent on the coil temperature, but it should increase the voltage across the coil as the coil self-heats.
** There will also be some change with the temperature of the materials involved in the magnetic circuit, but usually that's relatively small.
$endgroup$
add a comment |
$begingroup$
A voltage regulator will adjust the current while keeping the voltage constant.
A current regulator adjusts the voltage to keep the current constant.
$endgroup$
add a comment |
Your Answer
StackExchange.ifUsing("editor", function () {
return StackExchange.using("mathjaxEditing", function () {
StackExchange.MarkdownEditor.creationCallbacks.add(function (editor, postfix) {
StackExchange.mathjaxEditing.prepareWmdForMathJax(editor, postfix, [["\$", "\$"]]);
});
});
}, "mathjax-editing");
StackExchange.ifUsing("editor", function () {
return StackExchange.using("schematics", function () {
StackExchange.schematics.init();
});
}, "cicuitlab");
StackExchange.ready(function() {
var channelOptions = {
tags: "".split(" "),
id: "135"
};
initTagRenderer("".split(" "), "".split(" "), channelOptions);
StackExchange.using("externalEditor", function() {
// Have to fire editor after snippets, if snippets enabled
if (StackExchange.settings.snippets.snippetsEnabled) {
StackExchange.using("snippets", function() {
createEditor();
});
}
else {
createEditor();
}
});
function createEditor() {
StackExchange.prepareEditor({
heartbeatType: 'answer',
autoActivateHeartbeat: false,
convertImagesToLinks: false,
noModals: true,
showLowRepImageUploadWarning: true,
reputationToPostImages: null,
bindNavPrevention: true,
postfix: "",
imageUploader: {
brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
allowUrls: true
},
onDemand: true,
discardSelector: ".discard-answer"
,immediatelyShowMarkdownHelp:true
});
}
});
Sign up or log in
StackExchange.ready(function () {
StackExchange.helpers.onClickDraftSave('#login-link');
});
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
StackExchange.ready(
function () {
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f425853%2fin-which-way-proportional-valves-are-controlled-solely-by-current%23new-answer', 'question_page');
}
);
Post as a guest
Required, but never shown
3 Answers
3
active
oldest
votes
3 Answers
3
active
oldest
votes
active
oldest
votes
active
oldest
votes
$begingroup$
A voltage regulator allows the load to take the current it wants, while forcing the terminal voltage to remain constant.
A current regulator allows the load to determine the terminal voltage it wants, while forcing the current to remain constant.
Either can be implemented with a mainly voltage-output stage (like an emitter or source follower) or mainly current-output stage (like a collector or drain). The only difference is which of the output voltage or output current is sensed and fed-back to control the output stage.
To address your main point, voltage is not the 'cause of current'. At least, not in the sense that stops 'current is the cause of voltage' also being true at the same time. You set up the conditions, and current flows. While you can calculate numerically what's happening, arguing around the word 'cause' is going to confuse you.
$endgroup$
add a comment |
$begingroup$
A voltage regulator allows the load to take the current it wants, while forcing the terminal voltage to remain constant.
A current regulator allows the load to determine the terminal voltage it wants, while forcing the current to remain constant.
Either can be implemented with a mainly voltage-output stage (like an emitter or source follower) or mainly current-output stage (like a collector or drain). The only difference is which of the output voltage or output current is sensed and fed-back to control the output stage.
To address your main point, voltage is not the 'cause of current'. At least, not in the sense that stops 'current is the cause of voltage' also being true at the same time. You set up the conditions, and current flows. While you can calculate numerically what's happening, arguing around the word 'cause' is going to confuse you.
$endgroup$
add a comment |
$begingroup$
A voltage regulator allows the load to take the current it wants, while forcing the terminal voltage to remain constant.
A current regulator allows the load to determine the terminal voltage it wants, while forcing the current to remain constant.
Either can be implemented with a mainly voltage-output stage (like an emitter or source follower) or mainly current-output stage (like a collector or drain). The only difference is which of the output voltage or output current is sensed and fed-back to control the output stage.
To address your main point, voltage is not the 'cause of current'. At least, not in the sense that stops 'current is the cause of voltage' also being true at the same time. You set up the conditions, and current flows. While you can calculate numerically what's happening, arguing around the word 'cause' is going to confuse you.
$endgroup$
A voltage regulator allows the load to take the current it wants, while forcing the terminal voltage to remain constant.
A current regulator allows the load to determine the terminal voltage it wants, while forcing the current to remain constant.
Either can be implemented with a mainly voltage-output stage (like an emitter or source follower) or mainly current-output stage (like a collector or drain). The only difference is which of the output voltage or output current is sensed and fed-back to control the output stage.
To address your main point, voltage is not the 'cause of current'. At least, not in the sense that stops 'current is the cause of voltage' also being true at the same time. You set up the conditions, and current flows. While you can calculate numerically what's happening, arguing around the word 'cause' is going to confuse you.
edited 22 hours ago
answered yesterday
Neil_UKNeil_UK
77.1k283176
77.1k283176
add a comment |
add a comment |
$begingroup$
"Controlled by current" does not mean that no voltage is required (although that might be true in some specialized situations), it means that current is what determines the action of the valve. So you should adjust the voltage in order to maintain a certain current if you want the valve "position" to be relatively stable. That adjustment is done automatically by a "constant current" circuit.
In the case of an electromagnet as in such a valve (or a relay for that matter) the mechanical force is proportional to the current through the coil**. The voltage, for a given current, will change depending on the temperature of the coil, so a constant current circuit should not only start off with a voltage dependent on the coil temperature, but it should increase the voltage across the coil as the coil self-heats.
** There will also be some change with the temperature of the materials involved in the magnetic circuit, but usually that's relatively small.
$endgroup$
add a comment |
$begingroup$
"Controlled by current" does not mean that no voltage is required (although that might be true in some specialized situations), it means that current is what determines the action of the valve. So you should adjust the voltage in order to maintain a certain current if you want the valve "position" to be relatively stable. That adjustment is done automatically by a "constant current" circuit.
In the case of an electromagnet as in such a valve (or a relay for that matter) the mechanical force is proportional to the current through the coil**. The voltage, for a given current, will change depending on the temperature of the coil, so a constant current circuit should not only start off with a voltage dependent on the coil temperature, but it should increase the voltage across the coil as the coil self-heats.
** There will also be some change with the temperature of the materials involved in the magnetic circuit, but usually that's relatively small.
$endgroup$
add a comment |
$begingroup$
"Controlled by current" does not mean that no voltage is required (although that might be true in some specialized situations), it means that current is what determines the action of the valve. So you should adjust the voltage in order to maintain a certain current if you want the valve "position" to be relatively stable. That adjustment is done automatically by a "constant current" circuit.
In the case of an electromagnet as in such a valve (or a relay for that matter) the mechanical force is proportional to the current through the coil**. The voltage, for a given current, will change depending on the temperature of the coil, so a constant current circuit should not only start off with a voltage dependent on the coil temperature, but it should increase the voltage across the coil as the coil self-heats.
** There will also be some change with the temperature of the materials involved in the magnetic circuit, but usually that's relatively small.
$endgroup$
"Controlled by current" does not mean that no voltage is required (although that might be true in some specialized situations), it means that current is what determines the action of the valve. So you should adjust the voltage in order to maintain a certain current if you want the valve "position" to be relatively stable. That adjustment is done automatically by a "constant current" circuit.
In the case of an electromagnet as in such a valve (or a relay for that matter) the mechanical force is proportional to the current through the coil**. The voltage, for a given current, will change depending on the temperature of the coil, so a constant current circuit should not only start off with a voltage dependent on the coil temperature, but it should increase the voltage across the coil as the coil self-heats.
** There will also be some change with the temperature of the materials involved in the magnetic circuit, but usually that's relatively small.
answered yesterday
Spehro PefhanySpehro Pefhany
209k5160422
209k5160422
add a comment |
add a comment |
$begingroup$
A voltage regulator will adjust the current while keeping the voltage constant.
A current regulator adjusts the voltage to keep the current constant.
$endgroup$
add a comment |
$begingroup$
A voltage regulator will adjust the current while keeping the voltage constant.
A current regulator adjusts the voltage to keep the current constant.
$endgroup$
add a comment |
$begingroup$
A voltage regulator will adjust the current while keeping the voltage constant.
A current regulator adjusts the voltage to keep the current constant.
$endgroup$
A voltage regulator will adjust the current while keeping the voltage constant.
A current regulator adjusts the voltage to keep the current constant.
answered yesterday
TransistorTransistor
85.9k784184
85.9k784184
add a comment |
add a comment |
Thanks for contributing an answer to Electrical Engineering Stack Exchange!
- Please be sure to answer the question. Provide details and share your research!
But avoid …
- Asking for help, clarification, or responding to other answers.
- Making statements based on opinion; back them up with references or personal experience.
Use MathJax to format equations. MathJax reference.
To learn more, see our tips on writing great answers.
Sign up or log in
StackExchange.ready(function () {
StackExchange.helpers.onClickDraftSave('#login-link');
});
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
StackExchange.ready(
function () {
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f425853%2fin-which-way-proportional-valves-are-controlled-solely-by-current%23new-answer', 'question_page');
}
);
Post as a guest
Required, but never shown
Sign up or log in
StackExchange.ready(function () {
StackExchange.helpers.onClickDraftSave('#login-link');
});
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
Sign up or log in
StackExchange.ready(function () {
StackExchange.helpers.onClickDraftSave('#login-link');
});
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
Sign up or log in
StackExchange.ready(function () {
StackExchange.helpers.onClickDraftSave('#login-link');
});
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Sign up using Google
Sign up using Facebook
Sign up using Email and Password
Post as a guest
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
Required, but never shown
1
$begingroup$
The answer is on the wiki third paragraph. There are several implementations on it as well.
$endgroup$
– Huisman
yesterday